Smart operations:

  • Remote start and stop facility
  • Microprocessor based auto-start controller for AMF operation
  • In – built event log (optional)

Safe to use:

  • In- built safety features like HWT1, LLOP2, LFL3, CHF4, RWL5
  • Equipped with fire retardant foam

Environment friendly:

  • Less noise with low vibrations
  • Clean emissions
  • Meets CPCB-II norms

Versatile

  • Compact
  • Easy access to all service points
  • Compatible with any AMF/PIU logic controller

HWT: high water temperature, 2LLOP: low lube oil pressure, 3LFL: low fuel level, 4CHF: charging failure, 5RWL: radiator water level.

ESCORTS Genset Technical Specification
DG Set Model Units ELG-7.5/10 ELG-15N ELG-20 ELG-25 ELG-30 ELG-35N/40N/45N ELG-62.5/70N
Rating kVA 7.5/10 15 20 25 30 35/40/45 62.5/70/75
Canopy Size L x H x W
(mm)
1500 x 950 x 1300 1950 x 950 x 1300 2300 x 930 x 1450 2300 x 1030 x
1450
2500 x 1050 x
1450
2800 x 1050 x 1500
Battery Ah 88 / 100 100 x 120 100 x 120 120
Starting System 12 V
Weight kg 600 750 850 1000 1080 1200
Fuel Tank Capacity liters 95 100 130 150
Engine Model G-12-II G-15-II G-20-II G-25-II G-30-II G-40-II G-62.5-II
Engine Power bhp 18 22 25 33 43 58 88
Rated Speed RPM 1500
No. of Cylinders 2 3 4
Bore mm 91 95 91 91 91 98
Stroke mm 110 110 110 110 110 122
Total Displacement cc 1430 1560 2145 2145 2145 3680
Lube Oil Sump Capacity liters 5 5 6.5 6.5 8.5 8.5
Compression Ratio 17.5 :01
Aspiration Natural Turbo Charged Turbo Charged Inter Cooled
Cooling System Water / Coolant
Flywheel Housing / Flywheel SAE3/SAE10
FIP MICO Bosch - Inline Pump, Mech - Governor
Emission Norms CPCB - II Compliant
Alternator
Type Brushless, H Class Insulation
Frequency Hz 50
Voltage volts 230 / 415
** Due to continues product update, specifications are subject to change without prior notice

Interested in knowing more about this product? Enquire Now